Isotech Gemini R, Model: 976
Be the first to review “Isotech Gemini R, Model: 976” Cancel reply
Related Products
Edgetech Portable Relative Humidity Calibrator, Model: RH-CAL
Edgetech Portable Relative Humidity Calibrator, Model: RH-CALEdgetech Portable Relative Humidity Calibrator, Model: RH-CAL
Edgetech Portable Relative Humidity Calibrator, Model: RH-CALUnlike other comparative systems RH CAL is entirely self-sufficient. It does not need compressed air or a water connection to operate, which allows this system to be truly portable.
RH CAL is a microprocessor based, programmable humidity calibration system that is at home in the metrology lab or out in the field performing on site NIST traceable humidity calibrations. The system offers the highest accuracy available for both relative humidity and ambient temperature.
With RH CAL, temperature and relative humidity are controlled independently; therefore, you are not limited to performing calibrations at the surrounding ambient temperature, which may not be appropriate for your unique calibration protocol. Using Edgetech’s Optical Chilled Mirror (OCM) primary measurement technique for traceability and feedback control, RH CAL is a standalone, portable humidity calibration system.
Contributing to RH CAL’s ease of use are features such as maintenance reducing Automatic Balance Cycle (ABC), an integral ambient temperature probe and D2 chilled mirror sensor which are located in the sample chamber providing not only superior accuracy but the fastest response.
Isotech Dry Block, Model: Jupiter
Isotech Dry Block, Model: JupiterIsotech Dry Block, Model: Jupiter
Isotech Dry Block, Model: JupiterIsotech Cyclops, Model: 878
Isotech Cyclops, Model: 878Edgetech DewMaster Chilled Mirror Hygrometer
Edgetech DewMaster Chilled Mirror HygrometerEdgetech DewMaster Chilled Mirror Hygrometer
Edgetech DewMaster Chilled Mirror HygrometerEdgetech Instruments field-proven chilled mirror technology.
One, two or three stage sensors available – integral or remote from controller.
NIST traceable calibration certificate.
Depression range choice of either 45, 65 or 95°C . (one, two or three-stage cooling)
Automatic Balance Control (ABC)
Automatically corrects for most mirror contaminants.
Automatically restandardizes the instrument.
You choose time and interval of restandardization,for best convenience.
Increase the length of unattended operation.
Dual alarm capability
User programmable.
Can be set for latching or auto-reset mode.
Form C for greater versatility.
Serial and analog outputs.
RS232 communication with terminal, printer, or computer
Remote programming.
Data output such as dewpoint and alarm status.
0-5 VDC, 4-20 mA, 0-10 VDC, or 0-20mA
User scalable to drive peripheral devices.
Available simultaneously, one output per measurement parameter.
Scalable throughout the entire operating range of psychrometric variables.
Program via front panel or remote serial port.
Pressure transducer input for psychrometric variable.